Compare commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
b62327413f |
@@ -1,6 +1,6 @@
|
||||
id: t11
|
||||
name: t11
|
||||
version: 2.15.31
|
||||
version: 2.16.1
|
||||
author: t11
|
||||
icon: ''
|
||||
desc: t11
|
||||
|
||||
@@ -294,6 +294,10 @@ def cmd_str():
|
||||
pressure_max = 0
|
||||
pressure_t0_ms = None
|
||||
|
||||
# 压力突变检测(上升沿触发)
|
||||
prev_adc_val = 0 # 上一次ADC值
|
||||
ADC_JUMP_THRESHOLD = 250 # 突变阈值:相邻两次采样差值超过此值视为突变
|
||||
|
||||
def _flush_pressure_buf(reason: str):
|
||||
nonlocal pressure_buf, pressure_sum, pressure_min, pressure_max, pressure_t0_ms, logger
|
||||
if not pressure_buf:
|
||||
@@ -375,18 +379,27 @@ def cmd_str():
|
||||
pressure_max = adc_val
|
||||
if len(pressure_buf) >= PRESSURE_BATCH_SIZE:
|
||||
_flush_pressure_buf("batch")
|
||||
# if adc_val >= 2000:
|
||||
# print(f"adc :{adc_val}")
|
||||
if adc_val >= config.ADC_TRIGGER_THRESHOLD:
|
||||
|
||||
# 压力突变检测:当前值与前一次值的差值超过阈值时触发
|
||||
adc_diff = adc_val - prev_adc_val
|
||||
if adc_diff >= ADC_JUMP_THRESHOLD and prev_adc_val > 0 :
|
||||
hardware_manager.start_idle_timer() # 重新计时
|
||||
diff_ms = current_time - last_adc_trigger
|
||||
if diff_ms < 3000:
|
||||
logger.info(f"[MAIN] 扳机触发过于频繁, {diff_ms}ms")
|
||||
prev_adc_val = adc_val
|
||||
continue
|
||||
last_adc_trigger = current_time
|
||||
# 触发前先把缓存刷出来,避免波形被长耗时处理截断
|
||||
# 触发前先把缓存刷出来
|
||||
_flush_pressure_buf("before_trigger")
|
||||
|
||||
if logger:
|
||||
logger.info(
|
||||
f"[TRIGGER] ▲ 压力突变触发! "
|
||||
f"adc={adc_val}, prev={prev_adc_val}, "
|
||||
f"diff=+{adc_diff}, t={current_time}ms"
|
||||
)
|
||||
|
||||
try:
|
||||
process_shot(adc_val)
|
||||
except Exception as e:
|
||||
@@ -395,9 +408,11 @@ def cmd_str():
|
||||
logger.error(f"[MAIN] 图像处理异常: {e}")
|
||||
import traceback
|
||||
logger.error(traceback.format_exc())
|
||||
time.sleep_ms(100)
|
||||
continue
|
||||
else:
|
||||
|
||||
prev_adc_val = adc_val
|
||||
|
||||
# 未触发时的显示逻辑
|
||||
# 未触发时的显示逻辑
|
||||
if config.SHOW_CAMERA_PHOTO_WHILE_SHOOTING:
|
||||
try:
|
||||
camera_manager.show(camera_manager.read_frame())
|
||||
@@ -405,7 +420,7 @@ def cmd_str():
|
||||
logger = logger_manager.logger
|
||||
if logger:
|
||||
logger.error(f"[MAIN] 显示异常: {e}")
|
||||
time.sleep_ms(5)
|
||||
time.sleep_ms(1)
|
||||
|
||||
except Exception as e:
|
||||
# 主循环的顶层异常捕获,防止程序静默退出
|
||||
|
||||
@@ -36,3 +36,4 @@
|
||||
# 2.15.24 空改测试
|
||||
# 2.15.25 修复整合后关机失败和ota格式更新问题
|
||||
# 2.15.26
|
||||
# 2.16.1 修复压力传感触发判断按照增量
|
||||
+1
-1
@@ -4,6 +4,6 @@
|
||||
应用版本号
|
||||
每次 OTA 更新时,只需要更新这个文件中的版本号
|
||||
"""
|
||||
VERSION = '2.15.31'
|
||||
VERSION = '2.16.1'
|
||||
|
||||
|
||||
|
||||
Reference in New Issue
Block a user