1 Commits
Author SHA1 Message Date
linyimin b62327413f feat: 压力传感触发判断 2026-08-11 17:35:30 +08:00
4 changed files with 33 additions and 17 deletions
+1 -1
View File
@@ -1,6 +1,6 @@
id: t11 id: t11
name: t11 name: t11
version: 2.15.31 version: 2.16.1
author: t11 author: t11
icon: '' icon: ''
desc: t11 desc: t11
+30 -15
View File
@@ -294,6 +294,10 @@ def cmd_str():
pressure_max = 0 pressure_max = 0
pressure_t0_ms = None pressure_t0_ms = None
# 压力突变检测(上升沿触发)
prev_adc_val = 0 # 上一次ADC值
ADC_JUMP_THRESHOLD = 250 # 突变阈值:相邻两次采样差值超过此值视为突变
def _flush_pressure_buf(reason: str): def _flush_pressure_buf(reason: str):
nonlocal pressure_buf, pressure_sum, pressure_min, pressure_max, pressure_t0_ms, logger nonlocal pressure_buf, pressure_sum, pressure_min, pressure_max, pressure_t0_ms, logger
if not pressure_buf: if not pressure_buf:
@@ -375,18 +379,27 @@ def cmd_str():
pressure_max = adc_val pressure_max = adc_val
if len(pressure_buf) >= PRESSURE_BATCH_SIZE: if len(pressure_buf) >= PRESSURE_BATCH_SIZE:
_flush_pressure_buf("batch") _flush_pressure_buf("batch")
# if adc_val >= 2000:
# print(f"adc :{adc_val}") # 压力突变检测:当前值与前一次值的差值超过阈值时触发
if adc_val >= config.ADC_TRIGGER_THRESHOLD: adc_diff = adc_val - prev_adc_val
if adc_diff >= ADC_JUMP_THRESHOLD and prev_adc_val > 0 :
hardware_manager.start_idle_timer() # 重新计时 hardware_manager.start_idle_timer() # 重新计时
diff_ms = current_time - last_adc_trigger diff_ms = current_time - last_adc_trigger
if diff_ms < 3000: if diff_ms < 3000:
logger.info(f"[MAIN] 扳机触发过于频繁, {diff_ms}ms") logger.info(f"[MAIN] 扳机触发过于频繁, {diff_ms}ms")
prev_adc_val = adc_val
continue continue
last_adc_trigger = current_time last_adc_trigger = current_time
# 触发前先把缓存刷出来,避免波形被长耗时处理截断 # 触发前先把缓存刷出来
_flush_pressure_buf("before_trigger") _flush_pressure_buf("before_trigger")
if logger:
logger.info(
f"[TRIGGER] ▲ 压力突变触发! "
f"adc={adc_val}, prev={prev_adc_val}, "
f"diff=+{adc_diff}, t={current_time}ms"
)
try: try:
process_shot(adc_val) process_shot(adc_val)
except Exception as e: except Exception as e:
@@ -395,17 +408,19 @@ def cmd_str():
logger.error(f"[MAIN] 图像处理异常: {e}") logger.error(f"[MAIN] 图像处理异常: {e}")
import traceback import traceback
logger.error(traceback.format_exc()) logger.error(traceback.format_exc())
time.sleep_ms(100)
continue prev_adc_val = adc_val
else:
if config.SHOW_CAMERA_PHOTO_WHILE_SHOOTING: # 未触发时的显示逻辑
try: # 未触发时的显示逻辑
camera_manager.show(camera_manager.read_frame()) if config.SHOW_CAMERA_PHOTO_WHILE_SHOOTING:
except Exception as e: try:
logger = logger_manager.logger camera_manager.show(camera_manager.read_frame())
if logger: except Exception as e:
logger.error(f"[MAIN] 显示异常: {e}") logger = logger_manager.logger
time.sleep_ms(5) if logger:
logger.error(f"[MAIN] 显示异常: {e}")
time.sleep_ms(1)
except Exception as e: except Exception as e:
# 主循环的顶层异常捕获,防止程序静默退出 # 主循环的顶层异常捕获,防止程序静默退出
+1
View File
@@ -36,3 +36,4 @@
# 2.15.24 空改测试 # 2.15.24 空改测试
# 2.15.25 修复整合后关机失败和ota格式更新问题 # 2.15.25 修复整合后关机失败和ota格式更新问题
# 2.15.26 # 2.15.26
# 2.16.1 修复压力传感触发判断按照增量
+1 -1
View File
@@ -4,6 +4,6 @@
应用版本号 应用版本号
每次 OTA 更新时,只需要更新这个文件中的版本号 每次 OTA 更新时,只需要更新这个文件中的版本号
""" """
VERSION = '2.15.31' VERSION = '2.16.1'